Contact Us
Tel: +86-757-83806031
Fax: +86-757-83806032
E-mail: sales@top-sensor.com
Address: Dongjiang Internation 2#, Lingnan Ave, Chancheng District, Foshan City, Guangdong Province.
Semiconductor Strain Gauges SPY

Semiconductor Strain Gauges SPY

Description Semiconductor strain gauge is used for making sensor the used elastic element of stress analysis of commonly. Sensitive coefficient less mechanical hysteresis and wide range of resistance and low transverse effect etc. It can be used to measure the stress distribution and components...

Description

Semiconductor strain gauge is used for making sensor the used elastic element of stress analysis of commonly. Sensitive coefficient less mechanical hysteresis and wide range of resistance and low transverse effect etc. It can be used to measure the stress distribution and components of force - electrical conversion. For machinery aviation ships bridges engineering structures such as the static measurement more complex stress analysis it can also be used to fulfill nonlinear compensation of foil sensor. The company not only can product various regular strain gauge and will provide you with the different requirements of the product such as temperature no basal type.


Features
nonlinear compensation of foil sensor    
machinery aviation ships bridges
Micro pressure sensor


Technical Data
Semiconductor strain gauge characteristics

Model Number

SYP-15

SYP-30

SYP-60

SYP-120

SYP-350

SYP-600

SYP-1000

Gage resistance(Ω)

15±5%

30±5%

60±5%

120±5%

350±5%

600±5%

1000±5%

Code

B、C

B、C

B、C

A、B、C

B、C

C

C、D

construction

0、F2、F3、F4、F5

0、F2、F3、F4、F5

0、F2、F3、F4、F5

0、F2、F3、F4、F5

0、F2、F3、F4、F5

0、F2、F3、F4、F5

C:0、F2、F3、F4、F5
D:0、F1、F3

K

100

100

120

A:150
B:120

150

200

C:200
D:150

TCR (%/℃)

0.10

0.10

0.15

0.13

0.30

0.45

C:0.40
D:0.30

TCGF (%/℃)

-0.12

-0.12

-0.18

A:-0.35
B:-0.18

-0.35

-0.48

C:-0.48
D:-0.35

maximum operating current(mA)

50

50

50

A:20
B:50

30

20

20

Strain limits(mε)

5000

5000

5000

5000

5000

5000

5000


Dimension


Semiconductor strain gauge (without substrate)

Code

configuration

size (mm)

Gage resistance

A

wpsE93A.tmp.png

1.27×0.22×(0.020~0.030)

15Ω、30Ω、60Ω、120Ω

B

wpsE93B.tmp.png

3.8×0.22×(0.020~0.030)

15Ω、30Ω、60Ω、120Ω、350Ω

C

wpsE93C.tmp.png

4.7×0.22×0.02

15Ω、30Ω、60Ω、120Ω、350Ω、600Ω、1000Ω

D

wpsE96B.tmp.png

6×0.22×0.02

1000Ω

① The copper wire length of Semiconductor strain gage (without substrate) is shorter than 6mm;
② The Max Custom copper wire length is 12mm.



图片1.jpg

Example: SYP 1000 C F3
explicate: P-Si Semiconductor strain gage
resistance: 1000Ω;
K: 200;
Silicon: 4.7×0.22×0.02;
Substrate size: 7×4。

Note: if there are other requirements or the size of the substrate or the silicon strip must be specified in the contract



Hot Tags: semiconductor strain gauges SPY, China, manufacturers, suppliers, factory, made in China
Inquiry